The Fertilizer page displays the current pressure detected and the current pressure limit for the alarm. Enter an alarm limit or access the diagnostics.
NOTE: If the current pressure exceeds the high alarm limit, the value is highlighted red.
You prefer an alarm when the fertilizer system exceeds an upper limit.
You change the fertilizer rate or another parameter that alters the operating pressure.
The alarm value is too close to the operating pressure and causes false alarms.
You prefer to disable the alarm.
A value near and above the observed pressure when operating at your target rate, your target pressure, and your target speed.
The upper operating range of the liquid fertilizer system.
The safe upper limit of the system to avoid component damage.
Edit Alarm— edit the pressure limit. Enable or disable the alarm. |
Edit Alarm |
Diagnostics— view the sensor information. |
Diagnostics |
Pressure— displays the current pressure detected by the liquid fertilizer sensors. Each sensor is displayed separately. |
Pressure |
If the quantity of sensors observed does not match the configuration, access the Sensor Setup page in the Equipment Manager application.
Minimum Operating Pressure: 103 kPa (1.0 bar) (15 psi)
Maximum Operating Pressure: 621 kPa (6.2 bar) (90 psi)
Do Not Exceed: 689 kPa (6.9 bar) (100 psi)
High Alarm— displays the current value for the upper pressure limit. If the value is zero, the alarm is disabled. NOTE: The default alarm setting is zero. |
High Alarm |
Advanced Settings— access further adjustments and less common settings. |
Advanced Settings |