Quick Links

Setup | Alarms

Setup | Alarms allows you to define the alarm limits for various functions on the implement.

You can change the values for when the bars in the graph change from black to amber. You cannot change the values for when the bars in the graph change from amber to red.

Graph Example

Items Accessible on Setup | Alarms Page:

Population High— allows you to define an alarm at a percentage over the target population. Population rates that exceed this percentage trigger the alarm.

Population Low— allows you to define an alarm at a percentage under the target population. Population rates that fall below this percentage trigger the alarm.

Singulation Low— allows you to define an alarm at the percentage of seed singulation that you want to exceed. When seed singulation falls below this percentage, the alarm is triggered. Singulation is the placement of single seeds in the seed furrow.

Seed Spacing CV— allows you to define an alarm that triggers when spacing inconsistency reaches an undesired level. The coefficient of variation (CV) is a value that represents the consistency of seed spacing based on sensor readings.

Advanced Settingsaccess further adjustments and less common settings.

Advanced Settings

Fertilizer High Pressure

Fertilizer High Pressure— allows you to define an alarm for the maximum pressure in the liquid fertilizer system.