Diagnostics | Fertilizer allows you to view the readings from the liquid fertilizer sensor.
Sensor Number— is the identifier for each sensor.
Supply Voltage— is the power currently provided to the sensor from the tractor.
Operating Range— 4.5—5.5 V
Input Voltage— is the voltage reading in response to pressure detected.
Maximum— 4.5 V
Minimum— 0.5 V
Pressure Sensed— is the pressure in the liquid fertilizer system.
Sensor Maximum— 1380 kPa (13.8 bar) (200 psi)
System Maximum— 690 kPa (13.8 bar) (100 psi)
Minimum— 0