For best accuracy when using AutoPath, machine, implement, and display application setup is recommended.
Planting with Tillage Source Operation
Post-Planting Application (Self-Propelled Applicator)
Post-Planting Application (Pull-Type Applicator)
Harvest (Self-Propelled Harvester)
Measure and enter implement dimensions in Equipment Manager application.
Set up a Virtual Implement profile if required.
NOTE: Use Virtual Implement on non SeedStar 2 and legacy implements.
Enter implement width in rows.
Install implement receiver and enter receiver dimensions in the Equipment Manager application.
Establish SF3 or RTK implement receiver correction (shared signal compatible).
4600 CommandCenter v2 server or 4640 Universal Display with an Automation 4.0 activation / subscription.
G5 Display with a valid license.
Calibrate machine and implement TCM.
NOTE: Accurate TCM calibration is critical to AutoPath performance. Use the advanced TCM calibration method if possible.
Optimize Implement Guidance pass to pass accuracy. (recommended)
Define the Organization, Client, Farm, and Field.
Set operation type to planting.
Set crop type to an annually planted row crop, such as corn.
Create AutoTrac guidance lines. Manually driven guidance lines may be used, but are not recommended.
Measure and enter implement dimensions in Equipment Manager application.
Set up a Virtual Implement profile if required.
NOTE: Use Virtual Implement on non SeedStar 2 and legacy implements.
Enter implement width in rows.
Install implement receiver and enter receiver dimensions in the Equipment Manager application.
Establish SF3 or RTK machine receiver correction.
Establish SF3 or RTK implement receiver correction (shared signal compatible).
4600 CommandCenter v2 server or 4640 Universal Display with an Automation 4.0 activation / subscription.
G5 Display with a valid license.
Calibrate machine and implement TCM.
NOTE: Accurate TCM calibration is critical to AutoPath performance. Use the advanced TCM calibration method if possible.
Optimize Implement Guidance pass to pass accuracy. (recommended)
Define the Organization, Client, Farm, and Field.
Set operation type to application and tillage.
NOTE: Tillage should be used as a secondary operation to define the number of rows and row spacing. Implements with a Rate Controller and older Air Carts do not support number of rows and row spacing.
Create AutoTrac guidance lines. Manually driven guidance lines may be used, but are not recommended.
Measure and enter implement dimensions in Equipment Manager application.
Set up a Virtual Implement profile if required.
NOTE: Use Virtual Implement on non SeedStar 2 and legacy implements.
Enter implement width in rows.
Install implement receiver and enter receiver dimensions in the Equipment Manager application.
Establish SF3 or RTK machine receiver correction.
Establish SF3 or RTK implement receiver correction (shared signal compatible).
4600 CommandCenter v2 server or 4640 Universal Display with an Automation 4.0 activation / subscription.
G5 Display with a valid license.
Calibrate machine and implement TCM.
NOTE: Accurate TCM calibration is critical to AutoPath performance. Use the advanced TCM calibration method if possible.
Optimize Implement Guidance pass to pass accuracy. (recommended)
Define the Organization, Client, Farm, and Field.
Set operation type to planting.
AutoPath data is included in the setup file.
Create guidance lines using AutoPath data.
Establish SF3 or RTK machine receiver correction.
Calibrate machine TCM.
NOTE: Accurate TCM calibration is critical to AutoPath performance. Use the advanced TCM calibration method if possible.
Define machine width or track spacing.
4600 CommandCenter v2 server or 4640 Universal Display with an Automation 4.0 activation / subscription.
G5 Display with a valid license.
AutoTrac RowSense and/or Vision is equipped. (recommended)
Define the Organization, Client, Farm, and Field.
Set operation type to application.
Set crop type set to an annually planted row crop, such as corn.
AutoPath data is included in the setup file.
Create guidance lines using AutoPath data.
Measure and enter implement dimensions in Equipment Manager application.
Set up Virtual Implement if required.
NOTE: Use Virtual Implement on non SeedStar 2 and legacy implements.
Establish SF3 or RTK machine receiver correction.
Calibrate machine TCM.
NOTE: Accurate TCM calibration is critical to AutoPath performance. Use the advanced TCM calibration method if possible.
Define machine width or track spacing.
4600 CommandCenter v2 server or 4640 Universal Display with an Automation 4.0 activation / subscription.
G5 Display with a valid license.
AutoTrac RowSense and/or Vision is equipped. (recommended)
Define the Organization, Client, Farm, and Field.
Set operation type to application.
Set crop type set to an annually planted row crop, such as corn.
AutoPath data is included in the setup file.
Create guidance lines using AutoPath data.
Measure and enter implement dimensions in Equipment Manager application.
Establish SF3 or RTK machine receiver correction.
Calibrate machine TCM.
NOTE: Accurate TCM calibration is critical to AutoPath performance. Use the advanced TCM calibration method if possible.
Define machine width, track spacing, or attach header.
4600 CommandCenter v2 server or 4640 Universal Display with an Automation 4.0 activation / subscription.
G5 Display with a valid license.
AutoTrac RowSense and/or Vision is equipped. (recommended)
Define the Organization, Client, Farm, and Field.
Set operation type to harvest.
Set crop type set to an annually planted row crop, such as corn.
AutoPath data is included in the setup file.
Create guidance lines using AutoPath data.
Measure and enter implement dimensions in Equipment Manager application.
Set up Virtual Implement if required.
NOTE: Use Virtual Implement on non SeedStar 2 and legacy implements.
Install implement receiver and enter receiver dimensions in the Equipment Manager application.
Establish SF3 or RTK machine receiver correction.
Establish SF3 or RTK implement receiver correction (shared signal compatible).
4600 CommandCenter v2 server or 4640 Universal Display with an Automation 4.0 activation / subscription.
G5 Display with a valid license.
Calibrate machine and implement TCM.
NOTE: Accurate TCM calibration is critical to AutoPath performance. Use the advanced TCM calibration method if possible.
AutoTrac RowSense and/or Vision is equipped. (recommended)
Define the Organization, Client, Farm, and Field.
Set operation type to harvest.
Set crop type set to an annually planted row crop, such as corn.
AutoPath data is included in the setup file.
Create guidance lines using AutoPath data.