Quick Links

SeedStar | Overview | Closing Wheels Status

Closing Wheel Status indicates the current status of the closing wheel system and any errors that are detected.

Status Indicator— shows the current state of the row cleaners. The status indicators flash while the system is adjusting the air pressure.

  • Green— indicates that the parameters are within a normal range.

Example: Air pressure is within 15% of the target.

Green

  • Amber— indicates that the parameters are near a normal range.

Example: Air pressure is within 15 to 25% of the target.

Amber

  • Red— indicates that the parameters are out of range.

Example: Air pressure is more than 25% from the target.

Red

  • Gray— indicates that the implement is raised and the closing wheel force is disabled (gray indicator).

Gray

Normal States— show a check mark to indicate that the air compressor tank-pressure, group pressure, and the sensors are in normal states.

Check Mark

Error States— show an exclamation point to indicate an error within the closing wheel system. A message appears indicating the source of the error.

Exclamation Point

Error State Message— accompanies the error state.

Low or High Group Pressure— indicates that the system did not reach the expected target before the adjustment timed out.

Retry— select to re-activate the attempt to reach the target pressure.

Retry

Sensor/Actuator Error— indicates the need to diagnose failures of the system components.

Low Tank Pressure— indicates that the air tank is not maintaining enough pressure to keep up with adjustments. Search for system leaks.

Closing Wheel Diagnostics— select to view closing wheel diagnostic information.

Diagnostics

Advanced Settings— access further adjustments and less common settings.

Advanced Settings