Diagnostics | Row Cleaners allows you to view the readings from the air pressure sensors.
Sensor Supply— is the power currently provided to the sensor from the tractor.
Maximum— 5.5 V
Wings— shows the downforce readings for the row units on the wing frames.
Center— shows the downforce readings for the row units on the center frame.
Upforce (all)— shows the upforce readings for all the row units.
Voltage— is the voltage reading in response to air pressure detected.
Maximum— 4.9 V
Minimum— 0.08 V
Pressure Sensed— is the pressure detected in the row cleaner system, not the air tank.