Quick Links

Diagnostics | Height-Drives

Diagnostics | Height-Drives allow you to configure the height-drives sensor to start and stop at different points in the raise and lower cycle.

Status Indicators:

Current Height— indicates the implement height and moves along the slide bar as the implement is raised and lowered.

Start Height— indicates the position where the seed meter motors start.

Stop Height— indicates the position where the seed meter motors stop.

Minimum: 0% - Fully lowered

Default: Start Height 50%

Default: Stop Height 25%

Maximum: 100% - Fully raised

Current Height

Start Height

Stop Height

Modify When:

Procedure to Modify:

  1. Configure the implement for field operation.

  2. Park in an area where the seed furrow openers can penetrate the soil to represent the planting position.

  1. Perform a sensor calibration if any adjustments have been made to the sensor or to the implement configuration. Select Calibration and follow the on-screen instructions.

Calibration

  1. Lower the implement to the plant position. Observe the Current Height indicator.

Current Height

  1. Raise the implement to the position that you want the seed meter motors to turn off. The recommended position is just as the gauge wheels lose contact with the soil.

NOTE: Settings below 20% are not recommended.

  1. Select Set to establish the stop height.

NOTE: The percentage shown on the Set button mirrors the frame position.

Set

Stop Height

  1. Raise the implement to the full height. Observe the Current Height indicator.

Current Height

  1. Lower the frame to the position that you want the seed meter motors to activate. The recommended position is just as the seed furrow openers contact the soil.

  1. Select Set to establish the start height.

NOTE: The percentage shown on the Set button mirrors the frame position.

Set

Start Height

  1. To make small adjustments to the set point without changing the height of the implement, select either the Start Height or Stop Height input box and enter a value for the implement position.

Input Box

  1. Select OK to save the settings or select Cancel to close without saving.

OK

Cancel